Laboratory pH, Conductivity & TDS Meters | TBT Scientific
Home / Products / Laboratory Meters
ELECTROCHEMICAL MEASUREMENT

Reliable Measurement for Routine Laboratory Analysis

Laboratory meters for accurate pH, conductivity and TDS measurement across research, quality control, water testing and industrial laboratory applications. TBT Scientific offers practical measurement solutions for laboratories requiring reliable day-to-day analysis with straightforward operation.

Automatic Temperature Compensation (ATC)
Multi-Point Digital Calibration
Replaceable Electrodes & Sensors
Laboratory Benchtop Meters
🧪
Benchtop Accuracy

±0.01 pH & 0.5% FS Conductivity

PRODUCT LINEUP

Our Laboratory Measurement Solutions

Engineered for demanding quality-control labs, academic research institutions, and industrial liquid analysis.

Laboratory pH Meter
ACIDITY & ALKALINITY 0.00 – 14.00 pH

Laboratory pH Meters

Reliable pH measurement solutions for routine laboratory analysis, research and quality-control applications. Available configurations are suitable for different sample matrices, buffer sets, and laboratory environments.

High-resolution digital pH & mV readout
Automatic Temperature Compensation (ATC)
Up to 3-point automated buffer recognition
Standard BNC connector for versatile electrodes
Typical Applications:
Water & Wastewater Pharmaceutical QC Food & Beverage Chemical Synthesis Environmental Testing Agriculture & Soil
Enquire About pH Meters →
CONDUCTIVITY & TDS µS/cm, mS/cm, ppm, mg/L

Conductivity & TDS Meters

Laboratory conductivity and TDS meters for measuring ionic conductivity and dissolved solids across water, environmental, and industrial applications. Instruments are selected according to required measurement range and sample conductivity levels.

Wide range electrical conductivity measurement
Accurate Total Dissolved Solids (TDS) estimation
Automatic temperature normalization (25°C)
Selectable cell constants (K=0.1, 1.0, 10.0)
Typical Applications:
Purified & RO Water Drinking Water Facilities Wastewater Treatment Pharma Purified Water Boiler Feed Water Industrial Cooling Systems
Enquire About Conductivity & TDS Meters →
Laboratory Conductivity Meter
SELECTION GUIDE

Choosing the Right Laboratory Meter

Match the instrument to your measurement. The appropriate meter depends on the parameter being measured, sample conductivity, accuracy tolerance, and compliance standards.

Measurement Requirement Recommended Instrument Standard Range / Sensitivity Ideal Application
Acidity / Alkalinity Testing Benchtop pH Meter 0.00 – 14.00 pH (±0.01 pH) Chemical synthesis, buffer preparation, routine quality control
Water Ionic Conductivity Conductivity Meter 0.01 µS/cm – 200 mS/cm Purified water, RO permeate, environmental river monitoring
Dissolved Solids Measurement TDS Meter 0.1 ppm – 100 ppt Drinking water quality, boiler water, agricultural salinity
Routine Multi-Parameter Water Testing Combined Cond / TDS Meter Auto-ranging conductivity & TDS Wastewater effluents, plant incoming water, municipal supplies
Regulated Quality Assurance High-Precision pH / mV System ±0.002 pH with GLP data memory Pharmaceutical release testing, pharmacopeial compliance

5 Key Factors to Consider Before Selecting:

01

Measurement Range

Select an instrument and cell constant (K) calibrated specifically for your expected values—from ultrapure water to brine solutions.

02

Accuracy & Resolution

Determine whether your facility requires standard 0.01 pH precision or research-grade 0.001 pH high-resolution stability.

03

Electrode / Sensor Choice

Selecting the right junction, reference electrolyte, and glass bulb composition is critical for viscous, oily, or low-ionic samples.

04

Temperature Compensation

Electrochemical readings drift significantly with temperature. Automatic Temperature Compensation (ATC) ensures reliable readings.

05

Calibration Buffers & Standards

Verify that the meter supports automated recognition of your laboratory's standard buffer sets (USA, NIST, or DIN).

SENSOR TECHNOLOGY

Electrodes, Sensors & Accessories

Supporting your complete measurement system. High accuracy depends on the combination of a quality meter and the correct electrochemical sensor.

🧪

Combination pH Electrodes

General purpose glass body, spear-tip electrodes for food/semi-solids, and flat-surface probes for surface pH testing.

BNC Standard Connection
⚡

Conductivity Cells

Platinum 2-pole and 4-pole conductivity cells with selectable constants (K=0.1 for pure water, K=1.0 for general water, K=10 for saline).

Built-in Temp Sensor
🌡️

Temperature Probes

Stainless steel ATC temperature probes providing fast thermal response and reliable digital compensation from 0 to 100°C.

Fast Thermal Response
🧴

Buffers & Standards

Traceable pH buffer solutions (pH 4.01, 7.00, 10.01), conductivity calibration standards, and 3M KCl electrode storage solutions.

NIST Traceable
CROSS-SECTOR TESTING

Applications Across Industries

Where TBT Scientific electrochemical meters provide dependable daily testing data.

💧

Water & Environmental

pH, conductivity, and dissolved solids measurement for drinking water purification, wastewater treatment, and river monitoring.

💊

Pharmaceutical Labs

Strict pharmacopeia testing of purified water (WFI), formulation pH adjustment, and documented QC release testing.

🥗

Food & Beverage

Acidity measurement in dairy, fruit juices, beer brewing, sauces, and monitoring process clean-in-place (CIP) conductivity.

⚗️

Chemical Manufacturing

Routine chemical synthesis monitoring, acid/base titrations, bath concentrations, and plating solution maintenance.

🔬

Research & Education

Academic chemistry teaching practicals, biochemical buffer preparations, and environmental research field samples.

⚙️

Industrial Quality Control

Cooling tower water management, boiler feed water conductivity, textile processing baths, and raw material verification.

TECHNICAL CONSULTATION

Need Help Selecting a Laboratory Meter?

Tell our measurement specialists your parameters, sample type, and laboratory environment. We will recommend the optimal meter and electrode combination.

Tell Us About Your Requirements:
Primary parameter to measure (pH, Conductivity, TDS, mV)
Sample type (pure water, aqueous, viscous, chemical, soil)
Expected measurement range & resolution requirements
Benchtop laboratory setup or portable field testing
Electrode type & calibration buffer requirements
Quantity required & destination location
Product Selection · Technical Specifications · Factory Calibration · Global Logistics Support
Scroll to Top